Circuit Breakers Miniaturised single pole rocker switch/thermal circuit breaker combining ON/OFF switching and extremely fast overload performance in a single component (S-type TO CBE to EN 60934/IEC 934). Under overload conditions an internal neon (f
- 1410-F110-P1F1-W14QE2-2.5A
- E-T-A
-
50:
14,91 €
-
Non-Stocked Lead-Time 6 Weeks
|
Mouser Part No
457-10P1F1W14QE22.5A
|
E-T-A
|
Circuit Breakers Miniaturised single pole rocker switch/thermal circuit breaker combining ON/OFF switching and extremely fast overload performance in a single component (S-type TO CBE to EN 60934/IEC 934). Under overload conditions an internal neon (f
|
|
Non-Stocked Lead-Time 6 Weeks
|
|
Min.: 50
Mult.: 50
|
|
|
1410-F1
|
Circuit Breakers
|
Miniature
|
2.5 A
|
240 VAC
|
28 VDC
|
1 Pole
|
Rocker
|
- 20 C
|
+ 70 C
|
Illuminated
|
|
|
|
|
Circuit Breakers Miniaturised single pole rocker switch/thermal circuit breaker combining ON/OFF switching and extremely fast overload performance in a single component (S-type TO CBE to EN 60934/IEC 934). Under overload conditions an internal neon (f
- 1410-F110-P1F1-W14QE3-1.5A
- E-T-A
-
50:
14,91 €
-
Non-Stocked Lead-Time 6 Weeks
|
Mouser Part No
457-10P1F1W14QE31.5A
|
E-T-A
|
Circuit Breakers Miniaturised single pole rocker switch/thermal circuit breaker combining ON/OFF switching and extremely fast overload performance in a single component (S-type TO CBE to EN 60934/IEC 934). Under overload conditions an internal neon (f
|
|
Non-Stocked Lead-Time 6 Weeks
|
|
Min.: 50
Mult.: 50
|
|
|
1410-F1
|
|
Thermal Overcurrent
|
1.5 A
|
240 VAC
|
28 VDC
|
1 Pole
|
Rocker
|
- 20 C
|
+ 70 C
|
Illuminated
|
|
|
|
|
Circuit Breakers Miniaturised single pole rocker switch/thermal circuit breaker combining ON/OFF switching and extremely fast overload performance in a single component (S-type TO CBE to EN 60934/IEC 934). Under overload conditions an internal neon (f
- 1410-F110-P1F1-W14QE3-6.3A
- E-T-A
-
50:
14,55 €
-
Non-Stocked Lead-Time 6 Weeks
|
Mouser Part No
457-10P1F1W14QE36.3A
|
E-T-A
|
Circuit Breakers Miniaturised single pole rocker switch/thermal circuit breaker combining ON/OFF switching and extremely fast overload performance in a single component (S-type TO CBE to EN 60934/IEC 934). Under overload conditions an internal neon (f
|
|
Non-Stocked Lead-Time 6 Weeks
|
|
Min.: 50
Mult.: 50
|
|
|
1410-F1
|
|
Thermal Overcurrent
|
6.3 A
|
240 VAC
|
28 VDC
|
1 Pole
|
Rocker
|
- 20 C
|
+ 70 C
|
Illuminated
|
|
|
|
|
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
- 3130-F110-H7T1-W12QY7-20A
- E-T-A
-
1:
33,71 €
-
Non-Stocked Lead-Time 6 Weeks
|
Mouser Part No
457-110H7T1W12QY720A
|
E-T-A
|
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
|
|
Non-Stocked Lead-Time 6 Weeks
|
|
Min.: 1
Mult.: 1
|
|
|
3130-F
|
|
Thermal Overcurrent
|
20 A
|
240 VAC
|
50 VDC
|
1 Pole
|
Rocker
|
- 30 C
|
+ 60 C
|
Illuminated
|
|
|
|
|
Circuit Breakers Miniaturised single pole rocker switch/thermal circuit breaker combining ON/OFF switching and extremely fast overload performance in a single component (S-type TO CBE to EN 60934/IEC 934). Under overload conditions an internal neon (f
- 1410-F110-P1F1-W14Q-3.15A
- E-T-A
-
1:
22,55 €
-
Non-Stocked Lead-Time 6 Weeks
|
Mouser Part No
457-110P1F1W14Q3.15A
|
E-T-A
|
Circuit Breakers Miniaturised single pole rocker switch/thermal circuit breaker combining ON/OFF switching and extremely fast overload performance in a single component (S-type TO CBE to EN 60934/IEC 934). Under overload conditions an internal neon (f
|
|
Non-Stocked Lead-Time 6 Weeks
|
|
Min.: 1
Mult.: 1
|
|
|
1410-F1
|
|
Thermal Overcurrent
|
3.15 A
|
240 VAC
|
28 VDC
|
1 Pole
|
Rocker
|
- 20 C
|
+ 70 C
|
Illuminated
|
|
|
|
|
Circuit Breakers Miniaturised single pole rocker switch/thermal circuit breaker combining ON/OFF switching and extremely fast overload performance in a single component (S-type TO CBE to EN 60934/IEC 934). Under overload conditions an internal neon (f
- 1410-F110-P1F1-W14QB2-10A
- E-T-A
-
50:
14,91 €
-
Non-Stocked Lead-Time 6 Weeks
|
Mouser Part No
457-110P1F1W14QB210A
|
E-T-A
|
Circuit Breakers Miniaturised single pole rocker switch/thermal circuit breaker combining ON/OFF switching and extremely fast overload performance in a single component (S-type TO CBE to EN 60934/IEC 934). Under overload conditions an internal neon (f
|
|
Non-Stocked Lead-Time 6 Weeks
|
|
Min.: 50
Mult.: 50
|
|
|
1410-F1
|
|
Thermal Overcurrent
|
10 A
|
240 VAC
|
28 VDC
|
1 Pole
|
Rocker
|
- 20 C
|
+ 70 C
|
Illuminated
|
|
|
|
|
Circuit Breakers Miniaturised single pole rocker switch/thermal circuit breaker combining ON/OFF switching and extremely fast overload performance in a single component (S-type TO CBE to EN 60934/IEC 934). Under overload conditions an internal neon (f
- 1410-F110-P1F1-W14QB3-10A
- E-T-A
-
50:
14,91 €
-
Non-Stocked Lead-Time 6 Weeks
|
Mouser Part No
457-110P1F1W14QB310A
|
E-T-A
|
Circuit Breakers Miniaturised single pole rocker switch/thermal circuit breaker combining ON/OFF switching and extremely fast overload performance in a single component (S-type TO CBE to EN 60934/IEC 934). Under overload conditions an internal neon (f
|
|
Non-Stocked Lead-Time 6 Weeks
|
|
Min.: 50
Mult.: 50
|
|
|
1410-F1
|
|
Thermal Overcurrent
|
10 A
|
240 VAC
|
28 VDC
|
1 Pole
|
Rocker
|
- 20 C
|
+ 70 C
|
Illuminated
|
|
|
|
|
Circuit Breakers Miniaturised single pole rocker switch/thermal circuit breaker combining ON/OFF switching and extremely fast overload performance in a single component (S-type TO CBE to EN 60934/IEC 934). Under overload conditions an internal neon (f
- 1410-F110-P1F1-W14QE2-10A
- E-T-A
-
50:
14,91 €
-
Non-Stocked Lead-Time 6 Weeks
|
Mouser Part No
457-110P1F1W14QE210A
|
E-T-A
|
Circuit Breakers Miniaturised single pole rocker switch/thermal circuit breaker combining ON/OFF switching and extremely fast overload performance in a single component (S-type TO CBE to EN 60934/IEC 934). Under overload conditions an internal neon (f
|
|
Non-Stocked Lead-Time 6 Weeks
|
|
Min.: 50
Mult.: 50
|
|
|
1410-F1
|
|
Thermal Overcurrent
|
10 A
|
240 VAC
|
28 VDC
|
1 Pole
|
Rocker
|
- 20 C
|
+ 70 C
|
Illuminated
|
|
|
|
|
Circuit Breakers Miniaturised single pole rocker switch/thermal circuit breaker combining ON/OFF switching and extremely fast overload performance in a single component (S-type TO CBE to EN 60934/IEC 934). Under overload conditions an internal neon (f
- 1410-F110-P1F1-W14QE3-10A
- E-T-A
-
1:
24,37 €
-
Non-Stocked Lead-Time 6 Weeks
|
Mouser Part No
457-110P1F1W14QE310A
|
E-T-A
|
Circuit Breakers Miniaturised single pole rocker switch/thermal circuit breaker combining ON/OFF switching and extremely fast overload performance in a single component (S-type TO CBE to EN 60934/IEC 934). Under overload conditions an internal neon (f
|
|
Non-Stocked Lead-Time 6 Weeks
|
|
Min.: 1
Mult.: 1
|
|
|
1410-F1
|
|
Thermal Overcurrent
|
10 A
|
240 VAC
|
28 VDC
|
1 Pole
|
Rocker
|
- 20 C
|
+ 70 C
|
Illuminated
|
|
|
|
|
Circuit Breakers Miniaturised single pole rocker switch/thermal circuit breaker combining ON/OFF switching and extremely fast overload performance in a single component (S-type TO CBE to EN 60934/IEC 934). Under overload conditions an internal neon (f
- 1410-F110-P1F1-W14QE4-10A
- E-T-A
-
50:
14,91 €
-
Non-Stocked Lead-Time 6 Weeks
|
Mouser Part No
457-110P1F1W14QE410A
|
E-T-A
|
Circuit Breakers Miniaturised single pole rocker switch/thermal circuit breaker combining ON/OFF switching and extremely fast overload performance in a single component (S-type TO CBE to EN 60934/IEC 934). Under overload conditions an internal neon (f
|
|
Non-Stocked Lead-Time 6 Weeks
|
|
Min.: 50
Mult.: 50
|
|
|
1410-F1
|
|
Thermal Overcurrent
|
10 A
|
240 VAC
|
28 VDC
|
1 Pole
|
Rocker
|
- 20 C
|
+ 70 C
|
Illuminated
|
|
|
|
|
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
- 3130-F110-P7T1-W12QR3-15A
- E-T-A
-
1:
53,61 €
-
Non-Stocked Lead-Time 6 Weeks
|
Mouser Part No
457-110P7T1W12QR315A
|
E-T-A
|
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
|
|
Non-Stocked Lead-Time 6 Weeks
|
|
Min.: 1
Mult.: 1
|
|
|
3130-F
|
|
Thermal Overcurrent
|
15 A
|
240 VAC
|
50 VDC
|
1 Pole
|
Rocker
|
- 30 C
|
+ 60 C
|
Illuminated
|
|
|
|
|
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
- 3130-F110-P7T1-W12QY6-10A
- E-T-A
-
1:
33,23 €
-
Non-Stocked Lead-Time 6 Weeks
|
Mouser Part No
457-110P7T1W12QY610A
|
E-T-A
|
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
|
|
Non-Stocked Lead-Time 6 Weeks
|
|
Min.: 1
Mult.: 1
|
|
|
3130-F
|
|
Thermal Overcurrent
|
10 A
|
240 VAC
|
50 VDC
|
1 Pole
|
Rocker
|
- 30 C
|
+ 60 C
|
Illuminated
|
|
|
|
|
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
- 3130-F110-P7T1-W12QY6-15A
- E-T-A
-
1:
33,02 €
-
Non-Stocked Lead-Time 6 Weeks
|
Mouser Part No
457-110P7T1W12QY615A
|
E-T-A
|
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
|
|
Non-Stocked Lead-Time 6 Weeks
|
|
Min.: 1
Mult.: 1
|
|
|
3130-F
|
|
Thermal Overcurrent
|
15 A
|
240 VAC
|
50 VDC
|
1 Pole
|
Rocker
|
- 30 C
|
+ 60 C
|
Illuminated
|
|
|
|
|
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
- 3130-F110-P7T1-W12QY6-20A
- E-T-A
-
1:
33,23 €
-
Non-Stocked Lead-Time 6 Weeks
|
Mouser Part No
457-110P7T1W12QY620A
|
E-T-A
|
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
|
|
Non-Stocked Lead-Time 6 Weeks
|
|
Min.: 1
Mult.: 1
|
|
|
3130-F
|
|
Thermal Overcurrent
|
20 A
|
240 VAC
|
50 VDC
|
1 Pole
|
Rocker
|
- 30 C
|
+ 60 C
|
Illuminated
|
|
|
|
|
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
- 3130-F110-P7T1-W12QY7-10A
- E-T-A
-
1:
38,47 €
-
Non-Stocked Lead-Time 6 Weeks
|
Mouser Part No
457-110P7T1W12QY710A
|
E-T-A
|
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
|
|
Non-Stocked Lead-Time 6 Weeks
|
|
Min.: 1
Mult.: 1
|
|
|
3130-F
|
|
Thermal Overcurrent
|
10 A
|
240 VAC
|
50 VDC
|
1 Pole
|
Rocker
|
- 30 C
|
+ 60 C
|
Illuminated
|
|
|
|
|
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
- 3130-F110-P7T1-W12QY7-20A
- E-T-A
-
1:
33,23 €
-
Non-Stocked Lead-Time 6 Weeks
|
Mouser Part No
457-110P7T1W12QY720A
|
E-T-A
|
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
|
|
Non-Stocked Lead-Time 6 Weeks
|
|
Min.: 1
Mult.: 1
|
|
|
3130-F
|
|
Thermal Overcurrent
|
20 A
|
240 VAC
|
50 VDC
|
1 Pole
|
Rocker
|
- 30 C
|
+ 60 C
|
Illuminated
|
|
|
|
|
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
- 3130-F110-P7T1-W14QR6-15A
- E-T-A
-
1:
33,23 €
-
Non-Stocked Lead-Time 6 Weeks
|
Mouser Part No
457-110P7T1W14QR615A
|
E-T-A
|
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
|
|
Non-Stocked Lead-Time 6 Weeks
|
|
Min.: 1
Mult.: 1
|
|
|
3130-F
|
|
Thermal Overcurrent
|
15 A
|
240 VAC
|
50 VDC
|
1 Pole
|
Rocker
|
- 30 C
|
+ 60 C
|
Illuminated
|
|
|
|
|
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
- 3130-F110-P7T1-W19QY2-10A
- E-T-A
-
1:
33,21 €
-
Non-Stocked Lead-Time 6 Weeks
|
Mouser Part No
457-110P7T1W19QY210A
|
E-T-A
|
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
|
|
Non-Stocked Lead-Time 6 Weeks
|
|
Min.: 1
Mult.: 1
|
|
|
3130-F
|
|
Thermal Overcurrent
|
10 A
|
240 VAC
|
50 VDC
|
1 Pole
|
Rocker
|
- 30 C
|
+ 60 C
|
Illuminated
|
|
|
|
|
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
- 3130-F110-P7T1-W19QY6-20A
- E-T-A
-
1:
38,43 €
-
Non-Stocked Lead-Time 6 Weeks
|
Mouser Part No
457-110P7T1W19QY620A
|
E-T-A
|
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
|
|
Non-Stocked Lead-Time 6 Weeks
|
|
Min.: 1
Mult.: 1
|
|
|
3130-F
|
Circuit Breakers
|
Thermal
|
20 A
|
240 VAC, 415 VAC
|
50 VDC
|
1 Pole
|
Rocker
|
- 30 C
|
+ 60 C
|
Illuminated
|
|
|
|
|
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
- 3130-F110-P7T1-W19QY7-10A
- E-T-A
-
1:
33,23 €
-
Non-Stocked Lead-Time 6 Weeks
|
Mouser Part No
457-110P7T1W19QY710A
|
E-T-A
|
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
|
|
Non-Stocked Lead-Time 6 Weeks
|
|
Min.: 1
Mult.: 1
|
|
|
3130-F
|
Circuit Breakers
|
Thermal
|
10 A
|
240 VAC, 415 VAC
|
50 VDC
|
1 Pole
|
Rocker
|
- 30 C
|
+ 60 C
|
Illuminated
|
|
|
|
|
Circuit Breakers Single pole switch/thermal circuit breaker (S-type TO CBE to EN 60934) with tease-free, trip-free, snap action mechanism. Designed for snap-in panel mounting utilising round hole or industry standard fuse-holder cut-out dimensions. Fe
- 1110-F21B-P1M1-0.5A
- E-T-A
-
50:
17,72 €
-
Non-Stocked Lead-Time 6 Weeks
|
Mouser Part No
457-1110F21BP1M10.5A
|
E-T-A
|
Circuit Breakers Single pole switch/thermal circuit breaker (S-type TO CBE to EN 60934) with tease-free, trip-free, snap action mechanism. Designed for snap-in panel mounting utilising round hole or industry standard fuse-holder cut-out dimensions. Fe
|
|
Non-Stocked Lead-Time 6 Weeks
|
|
Min.: 50
Mult.: 50
|
|
|
1110-Fx12-P1M1
|
|
Thermal Overcurrent
|
500 mA
|
250 VAC
|
50 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers Single pole switch/thermal circuit breaker (S-type TO CBE to EN 60934) with tease-free, trip-free, snap action mechanism. Designed for snap-in panel mounting utilising round hole or industry standard fuse-holder cut-out dimensions. Fe
- 1110-F21B-P1M1-10A
- E-T-A
-
50:
15,10 €
-
Non-Stocked Lead-Time 6 Weeks
|
Mouser Part No
457-1110F21BP1M110A
|
E-T-A
|
Circuit Breakers Single pole switch/thermal circuit breaker (S-type TO CBE to EN 60934) with tease-free, trip-free, snap action mechanism. Designed for snap-in panel mounting utilising round hole or industry standard fuse-holder cut-out dimensions. Fe
|
|
Non-Stocked Lead-Time 6 Weeks
|
|
Min.: 50
Mult.: 50
|
|
|
1110-Fx12-P1M1
|
|
Thermal Overcurrent
|
10 A
|
250 VAC
|
50 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers Miniaturised single pole thermal circuit breaker with push-to-reset tease-free, trip-free, snap action mechanism (R-type TO CBE to EN 60934), snap-in panel mounting. For lower current ratings see type 105. Approved to CBE standard EN
- 1140-F111-P1M1-10A
- E-T-A
-
1:
20,28 €
-
Non-Stocked Lead-Time 6 Weeks
|
Mouser Part No
457-1140F111P1M110A
|
E-T-A
|
Circuit Breakers Miniaturised single pole thermal circuit breaker with push-to-reset tease-free, trip-free, snap action mechanism (R-type TO CBE to EN 60934), snap-in panel mounting. For lower current ratings see type 105. Approved to CBE standard EN
|
|
Non-Stocked Lead-Time 6 Weeks
|
|
Min.: 1
Mult.: 1
|
|
|
1140
|
Miniature Circuit Breakers
|
Overcurrent Protection
|
10 A
|
240 VAC
|
48 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers Miniaturised single pole thermal circuit breaker with push-to-reset tease-free, trip-free, snap action mechanism (R-type TO CBE to EN 60934), snap-in panel mounting. For lower current ratings see type 105. Approved to CBE standard EN
- 1140-F111-P1M1-12A
- E-T-A
-
1:
20,28 €
-
Non-Stocked Lead-Time 6 Weeks
|
Mouser Part No
457-1140F111P1M112A
|
E-T-A
|
Circuit Breakers Miniaturised single pole thermal circuit breaker with push-to-reset tease-free, trip-free, snap action mechanism (R-type TO CBE to EN 60934), snap-in panel mounting. For lower current ratings see type 105. Approved to CBE standard EN
|
|
Non-Stocked Lead-Time 6 Weeks
|
|
Min.: 1
Mult.: 1
|
|
|
1140
|
Miniature Circuit Breakers
|
Overcurrent Protection
|
12 A
|
240 VAC
|
48 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
- 3120-N311-P7T1-W12FY3-10A
- E-T-A
-
1:
32,33 €
-
Non-Stocked Lead-Time 6 Weeks
|
Mouser Part No
457-11P7T1W12FY310A
|
E-T-A
|
Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
|
|
Non-Stocked Lead-Time 6 Weeks
|
|
Min.: 1
Mult.: 1
|
|
|
3120-N
|
Thermal Circuit Breakers
|
Overcurrent Protection
|
10 A
|
115 VAC
|
50 VDC
|
1 Pole
|
Rocker
|
- 30 C
|
+ 60 C
|
Illuminated
|
|
|