Current Sensor Current Sensors – Industrial

Filters

Availability options
Applied filters
Select Image Part # Mfr. Description Datasheet Availability Pricing (EUR) Filter the results in the table by unit price based on your quantity. Qty. RoHS ECAD Model Current Rating Sensor Type Output Type Frequency Range Accuracy Supply Voltage - Min Supply Voltage - Max Response Time Minimum Operating Temperature Maximum Operating Temperature
Pulse Egston Current Sensors – Industrial Clamps Rogowski Integrator10 5V 19In Stock
Min.: 1
Mult.: 1

7.8 mA 45 Hz to 65 Hz 4.5 V 5.5 V - 20 C + 80 C
Bourns Current Sensors – Industrial 1000 AMP 35 WATT 30PPM
10Expected 21/10/2026
Min.: 1
Mult.: 1

1 kA Analog 0.2 % 1.6 us - 40 C + 115 C
Bourns Current Sensors – Industrial 100 AMP 4 WATT 30PPM
10Expected 21/10/2026
Min.: 1
Mult.: 1

100 A Analog 0.2 % 1.6 us - 40 C + 115 C
Bourns Current Sensors – Industrial 250 AMP 9 WATT 30PPM
10Expected 21/10/2026
Min.: 1
Mult.: 1

250 A Analog 0.2 % 1.6 us - 40 C + 115 C
Bourns Current Sensors – Industrial 500 AMP 17 WATT 30PPM
10Expected 21/10/2026
Min.: 1
Mult.: 1

500 A Analog 0.2 % 1.6 us - 40 C + 115 C
Bourns Current Sensors – Industrial SSD-1000A-C CURRENT SENSOR
7Expected 09/10/2026
Min.: 1
Mult.: 1

1 kA Digital 0.1 % 5 VDC 60 VDC - 40 C + 115 C
Bourns Current Sensors – Industrial SSD-1000A-C CURRENT SENSOR with T resistor
1Expected 11/11/2026
Min.: 1
Mult.: 1

1 kA Digital 0.1 % 5 VDC 60 VDC - 40 C + 115 C
Pulse Egston Current Sensors – Industrial Clamps Rogowski Integrator10 12V
10Expected 09/10/2026
Min.: 1
Mult.: 1

7.8 mA 45 Hz to 65 Hz 10.8 V 13.2 V - 20 C + 80 C
Pulse Egston Current Sensors – Industrial Clamps Rogowski Integrator10 24V
10Expected 09/10/2026
Min.: 1
Mult.: 1

7.8 mA 45 Hz to 65 Hz 21.6 V 26.4 V - 20 C + 80 C
Bourns Current Sensors – Industrial SSD-1000A-CA CURRENT SENSOR Non-Stocked Lead-Time 8 Weeks
Min.: 1
Mult.: 1

1 kA Closed Loop 0.1 % 5 VDC 60 VDC - 40 C + 115 C
Bourns Current Sensors – Industrial SSD-1000A-CA CURRENT SENSOR with T resistor Non-Stocked Lead-Time 8 Weeks
Min.: 1
Mult.: 1

1 kA Closed Loop 0.1 % 5 VDC 60 VDC - 40 C + 115 C
Bourns Current Sensors – Industrial SSD-1000A-R CURRENT SENSOR Non-Stocked Lead-Time 8 Weeks
Min.: 1
Mult.: 1

1 kA Digital 0.1 % 5 VDC 60 VDC - 40 C + 115 C
Bourns Current Sensors – Industrial SSD-1000A-R CURRENT SENSOR with T resistor Non-Stocked Lead-Time 8 Weeks
Min.: 1
Mult.: 1

1 kA Digital 0.1 % 5 VDC 60 VDC - 40 C + 115 C
Bourns Current Sensors – Industrial SSD-1000A-RA CURRENT SENSOR Non-Stocked Lead-Time 8 Weeks
Min.: 1
Mult.: 1

1 kA Closed Loop 0.1 % 5 VDC 60 VDC - 40 C + 115 C
Bourns Current Sensors – Industrial SSD-1000A-RA CURRENT SENSOR with T resistor Non-Stocked Lead-Time 8 Weeks
Min.: 5
Mult.: 1

1 kA Closed Loop 0.1 % 5 VDC 60 VDC - 40 C + 115 C