25 mm Board Mount Current Sensors

Results: 14
Select Image Part # Mfr. Description Datasheet Availability Pricing (EUR) Filter the results in the table by unit price based on your quantity. Qty. RoHS ECAD Model Current Rating Sensor Type Response Time Frequency Range Operating Supply Voltage Output Type
Tamura Board Mount Current Sensors CURRENT SENSOR ( 25A; 15V) 22In Stock
Min.: 1
Mult.: 1

25 A Open Loop 5 us 0 Hz to 100 kHz 15 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 3A;15V) Non-Stocked Lead-Time 24 Weeks
Min.: 400
Mult.: 400

3 A Open Loop 5 us 0 Hz to 100 kHz 15 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 3A;+5V) Non-Stocked Lead-Time 24 Weeks
Min.: 400
Mult.: 400

3 A Open Loop 5 us 0 Hz to 100 kHz 5 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 5A;15V) Non-Stocked Lead-Time 24 Weeks
Min.: 400
Mult.: 400

5 A Open Loop 5 us 0 Hz to 100 kHz 15 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 10A; 15V) Non-Stocked Lead-Time 24 Weeks
Min.: 400
Mult.: 400

10 A Open Loop 5 us 0 Hz to 100 kHz 15 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 10A; +5V) Non-Stocked Lead-Time 24 Weeks
Min.: 400
Mult.: 400

10 A Open Loop 5 us 0 Hz to 100 kHz 5 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 15A; 15V) Non-Stocked Lead-Time 24 Weeks
Min.: 400
Mult.: 400

15 A Open Loop 5 us 0 Hz to 100 kHz 15 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 20A; 15V) Non-Stocked Lead-Time 24 Weeks
Min.: 400
Mult.: 400

20 A Open Loop 5 us 0 Hz to 100 kHz 15 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 30A; 15V) Non-Stocked Lead-Time 24 Weeks
Min.: 400
Mult.: 400

30 A Open Loop 5 us 0 Hz to 100 kHz 15 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 5A;+5V) Non-Stocked Lead-Time 24 Weeks
Min.: 400
Mult.: 400
No
5 A Open Loop 5 us 0 Hz to 100 kHz 5 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 15A; +5V) Non-Stocked Lead-Time 24 Weeks
Min.: 400
Mult.: 400
No
15 A Open Loop 5 us 0 Hz to 100 kHz 5 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 20A; +5V) Non-Stocked Lead-Time 24 Weeks
Min.: 400
Mult.: 400
No
20 A Open Loop 5 us 0 Hz to 100 kHz 5 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 25A; +5V) Non-Stocked Lead-Time 24 Weeks
Min.: 400
Mult.: 400
No
25 A Open Loop 5 us 0 Hz to 100 kHz 5 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 30A; +5V) Non-Stocked Lead-Time 24 Weeks
Min.: 400
Mult.: 400
No
30 A Open Loop 5 us 0 Hz to 100 kHz 5 V Analog - Voltage